The Shand & Jurs Biogas Model 97180 Foam Separator is designed for
use in piping systems to remove foam caused by agitation from the digester
discharge gas. The foam must be dispersed and collected in order to protect
downstream equipment from corrosion or clogging. The Foam Separator is typically
installed in the digester gas piping.
Foam is removed from the gas as it flows
through the separator by subjecting the gas/foam mixture to a direct spray of
water inside the separator. The gas then rises vertically past an internal
baffle in order to flow from the tank. Foam and solids are heavier than gas,
and the combination of the large vertical rise the gas has to travel, and the
continuous spray of water will knock the foam out of the gas and direct it to
the bottom of the chamber. The foam is removed via a drain connection. An
optional visual flow indicator is provided in the drain line to confirm water
flow.
Liquid level switches allow high and low level alarms to be used. At
low water condition, source power is routed through the low-level switch to a
low water alarm. Once the water level rises above the low-level switch, power
is routed to the water solenoid valve energizing it open. If for any reason,
the water level rises above the high level switch, power is then routed to a
high level alarm. At this high level condition, the knock-down water solenoid
valve is de-energized closed which stops the water flow.
|