Model 613 / 713

Single Stage / Two Stage Top Mounted
Level Control Switches with Porcelain Displacers


Omnitrol - Model 613/713 Top Mounted Level Control Switches with Porcelain Displacers
  • Low Cost Porcelain Displacer Material
  • Simple adjustment of displacers for various switching differentials
  • Cone top displacers shed debris floating in liquid (such as sewage)
  • UL & CSA approved


The Omnitrol Model 613 single stage control and the Model 713 two stage, (Dual Actuator), control are top mounted level switches of the adjustable differential type and utilize porcelain as standard displacer material. Porcelain offers several advantages such as low cost and high density for use in applications such as sewage, oils, paints and foaming and surging liquids. The displacer is styled, and the surface glazed, to help prevent adherence of oils and other contaminants common to applied processes. These controls have solid displacers which are unaffected by pressure, leakage, and collapsing. With a simple field adjustment the displacer can be positioned to any desired elevation below the mounting connection to open and/or close an electric or pneumatic switch.

The distance between the ON/OFF or OPEN/ CLOSE is adjustable from the minimum (tables 1 and 2), to the maximum length of the cable, which is 10 feet standard. Controls may be supplied with cables up to 60 feet for 600 series and 40 feet for 700 series.

The pressure, temperature and specific gravity in which these controls may be applied is a function of the selected mounting connection and displacer assembly. Model 613 or 713 may be used for pressures up to 1500 PSIG with standard construction and for specific gravities as low as 0.50, for the 613, and 0.60 for the 713.

Do not use porcelain displacers in closed, non-vented, boiling water condensate systems over 200º F (93º C).

Table 1 Minimum Switching Differentials vs. Specific Gravity for the 613, 2-1/2” Diameter Displacer
Specific Gravity 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 .95 .90 .85 .80 .75 .70 .65 .60 .55 .50
Differential Inches 1.72 1.81 1.91 2.02 2.15 2.30 2.49 2.70 2.84 2.98 3.10 3.31 3.51 3.74 4.00 4.32 4.68 5.12
Differential mm. 44 46 48 51 55 58 63 69 72 76 79 84 89 95 102 110 119 130

Table 2 Minimum Switching Differentials vs. Specific Gravity for the 713, 2-1/2” Diameter Displacer
Specific Gravity 1.2 1.1 1.0 .95 .90 .85 .80 .75 .70 .65 .60 .55 .50
Differential Inches 2.30 2.49 2.70 2.84 2.98 3.10 3.31 3.51 3.74 4.00 4.32 4.68 5.12
Differential mm. 58 63 69 72 76 79 84 89 95 102 110 119 130