L&J Engineering The single source for all your Level Gauging needs. L&J Technologies


L&J Technologies
L&J Eng. Home

Products:
Level Gauges
 Radar
 Servo
 Tape Gauges
 Transmitters
 Magnetostrictive
 Direct Digital
 4-20mA Input
Inventory Control
RTU's
Level Alarms
Temperature Probes
Wireless
Calibration

PDF's
Site Map

Search: L&J Engineering




Companies:
 Delavan
 Durlam
 GPE
 Omnitrol
 Shand&Jurs
 Shand&Jurs BioGas


L&J Technologies is ISO 9001 Registered



SPECIFICATIONS
Accuracy: 1/16th" (1.6mm) Std.
1/32nd" (0.8mm) Opt.
Range: 0-96 Feet (0-29M)
Shaft Rotation: Selectable - Clockwise or
Counterclockwise
Digital Conversion: Absolute Optic Encoding
Calibration Feet and 1/16th"
Feet and 1/32",Millimeter
Power Consumption: 35V DC, 20mA (Tankway™)
Power Options: 24/48/65/110/220 VAC
24/35-60 VDC
Temperature
Inputs:  Platinum or Copper
Sensing:  Spot 3-Wire RTD(1-2),
Average Temp. (Opt.)*
Accuracy: 0.5º F (0.3º C)
Resolution:  0.1º F (0.06º C)
Baud Rate: 300-9600 Selectable
Lightning Protection: Comprehensive Surge Protection
Control Option: 2 Points (Valves and/or pumps)
I/O Option: 2 4-20mA Output
4 4-20mA Input
4 Programmable Dry Contacts
6 CAM Switches
Field Wires: 4-Field Wires, (Tankway™)
20AWG Minimum
Protocol: Plugin modules for most protocols: Modbus,Profibus,Hart,Enraf,Varec,
TI-Way,GPE
Safety Approvals: Explosion Proof/*Intrinsically Safe
Class I, Div. 1, Groups C&D
UL (SS/SSI/SFI), CSA (SS)EEx d IIB T6  BASEEFA (SS),CENELEC (SS),SAA (SS)

Lightning Protection

All L&J equipment, including the MCG 2000SFI, comes standard with comprehensive lightning and surge protection. This is provided in an external condulet housing and is made up of tranzorbs, gas discharge tubes, and in-line fuse resistors on all four lines.

Transient voltages are generated by switching loads, static discharges, lightning and other electrical disturbances. The MCG 2000SFI has a lightning suppression system which is both sensitive and fast acting to protect the more expensive electronics inside the transmitter. The resistor tranzorb network shunts small transients to ground. If a large enough potential is built up across them, the gas discharge tube is fired draining large currents to the ground.


Smart Flash Promotes Reprogramming

With the new processing power in the MCG 2000SFI L&J can now offer plug-in interface modules. There are parts to any interface protocol, software and hardware.

The software protocol or actual bit structure of the data is programmed into the on-board logic chip. Several different software protocols can be programmed in the same unit.

The hardware for the specific interface protocol (i.e. RS232, RS485, Tankway™, etc.) is provided in a plug-in module. This allows a customer to replace his existing system over several phases (if required). For example, a customer can immediately replace their existing non-L&J transmitters with an MCG 2000SFI containing the appropriate interface module. At a later date, when the entire system is replaced by an L&J system, the old interface module can be replaced with a Tankway™ or other standard module.

FEATURE GAUGE A GAUGE B MCG 2000SFI
Standard Transmission Distance > 4 miles    
More than 15 standard protocol output Options    
Lightning and Surge suppression
Absolute Encoding    
Optical Encoding  
Precision Machined Drive Gear N/A
Battery Free Operation  
0.8mm (32nd ") Accuracy Available (std. 1/16th ")    
Configurable Discrete Switch Outputs Avail.    
Integral CAM Switches Available    
Standard LCD Display Built-In    
LCD Contrast control From Remote IR    
Analog Input and Output Options
Control Options for Operator V&P Control    
Spot and Average Temp. Inputs Available    
Flash ROM    
Program revisions available from communication bus    
Remote Transmitter Parameter Test Capabilities    
Remote Field Wiring Test Capabilities    
Configurable w/o Hardwire Connection
  • Gauge Type
  • Encoder Type
  • Display Format
  • Temp input (Spot or Avg)
  • RTD (CU or PL)
  • Comm. Format
  • Level Calibration
  • Temperature Calibration
  • Gage Rotation
  • Device Address
   

2000SFI brochure Download 2000SFI PDF






<-Prev  1  2  3 

L&J Engineering
©Copyright L&J Technologies 2008