SPECIFICATIONS
Measuring Principle: FMCW Radar
Range: 0-75 (23m) feet Standard.
Up to 180 feet (55m) optional
Accuracy: +/-0.5mm*
Resolution: .1 mm
Radar Power: Less than 1mw (0dBm)
Electronics Temperature: -40º F to 150º F
(-40ºC to +65º C)
Product Temperature: -148º F to 482º F
(-100º C to 250º C)
Local Display: 2 line, 80 Character LCD
Optional Remote Display: Ground Level Display
(4 line 80 LCD)
Communications: L&J "Tankway" (standard)
Up to 128 MCG field devices
Other Mfgrs. Protocols
I/O Option: Two 4-20mA Outputs
Two 4-20 mA Inputs
Temp Option: Single or dual RTD
Temp Avg. Probe (CU/PT)
Control Options: 2 points, 4 contacts
Power: 110VAC, 240VAC,
24VDC, 10W
Other voltages available
Lightning Protection: Comprehensive Surge
Protection Standard
Max. Pressure: 150PSIG (or 300PSIG optional)
Construction: Cast Aluminum Std.
Stainless Steel Opt.
Mounting: 2" NPT
Standard, Others
Optional including DIN and JIS/TD>
Weight: 8 lbs. - AL
Safety Approvals: Explosion Proof/ **Intrinsically Safe Temp., Class I, Div. 1,
Group B, C & D, UL, CUL
Approved, FCC APPROVED

Antennas: Parabolic, Cone, Rod, Stillwell
*depends on installation, application, type of  antenna and product dielectric properties
**requires MCG 2350 accessory
All designs subject to change. Certified dimensions and specifications available upon request.

Simple Plug-In Modules

Part of L&J Engineering's expertise lies in its flexibility and ability to emulate competitive protocols therefore allowing L&J equipment to interface with non-L&J field equipment.

The software protocol or actual bit structure of the data is programmed into the on-board logic chip. Several different software protocols can be programmed in the same unit.

The hardware for the specific interface protocol (i.e. RS232,RS485,Tankway™, etc.) is provided in a plug-in module. This allows a customer to replace his existing system over several phases (if required). For example, a customer can immediately replace his existing non-L&J gauge with an MCG 1600SFI Series Radar Gauge containing the appropriate interface module. At a later date, when the entire system is replaced by an L&J system, the old interface module can be replaced with a Tankway™ module.



Click on Images for Enlarged View

1600sfi Radar Dimensions


1600_board.jpg, 150*150 1600sf_condulet_board.jpg, 149*150

MCG 1600SFI RADAR GAUGING SYSTEM

1600sfiintank.jpg, 200*184

pdficon Download PDF Brochure