Specifications
Resolution:0.4mm (0.016'')
Accuracy:± 0.4mm (0.016'')
Sensitivity:± 0.01mm (± 0.004'')
Measuring Range:0 - 75’ (22m) (standard)
0 - 150’ (46m) (optional)
Temp. Accuracy:0.5º F (.3º C)
Temp. Resolution:0.1º F (.06º C)
Temp. Measurement:Single, Dual or Triple RTD
*Temperature Averaging
Density Accuracy:5 kg/m³
Level Encoding:Optical
Display:4-line x40 character LCD
Communication:L&J “Tankway”,Others optional
Baud Rate:300-9600 Selectable
Field Wires:4 Field Wires(Tankway)up to 128 MCG Field Devices per Highway
Static Power Consumption:200 mA at 110 VAC
Power Options:220 VAC, 110 VAC, 65 VAC, 48 VAC,24 VAC, 48 VdC, 24 VdC
Lightning Protection:Comprehensive Surge Protection
Control Option:2 points (Valves and Pumps)
(2DI, 6DO) 6 - Contacts
I/O Option:Two 4-20mA out, Three 4-20mA in
(Isolated Outputs Optional)
Operating Temperature:
Drum Chamber: -40º F to 600º F (-40º C to 315º C)
Elec. Chamber: -40º F to 185º F (-40º C to 85º C)
Mounting:2” 150lb. ANSI Flange Standard;
other sizes and DIN sizes optional
Body Material:AL, SS
Weight:AL-25 lbs, (11.37 kg)
Pressure:Atmospheric (25 psi), 150 psi or 300 psi optional
Safety Approvals:Explosion Proof, Class I,Div.1 Group C&D, Group B optional,UL, CUL Approved EExd IIB T6, CENELEC
*requires MCG 2350 accessory

Engineered To Perform Application Versatility

The servo housing is divided into two sections, the drum chamber and the electronics chamber. While only stainless steel parts are utilized inside the drum (which is open to product), the servo housing is available in cast aluminum or stainless steel. The drum chamber is isolated from the electronics chamber by a magnetic coupling. The electronic chamber is gas-tight, explosion proof, and isolates the electrical components from the product environment and the atmosphere. The MCG 1500SFI typically communicates the standard L&J “Tankway” 4-wire data highway. Yet simple plug-in modules can be utilized to provide for emulation of most existing, as well as custom field protocols or analog outputs.

Simplicity of Design = Ease of Serviceability

With only 3 moving parts (drum assembly, gear assembly, and stepper motor) and only two PC boards (the CPU and the strain gauge amplifier), L&J has minimized parts to maximize reliability. The modular assembly permits the stocking of just a few components. This all means that there are less moving parts to wear out and replace, and the parts which may need service or repair are modular and interchangeable so less need to be stocked.

L&J maintains a stock of spare parts as well as a full service staff which, together, guarantee quick turn-around on any part that is sent in for repair. On-site repairs can be made on servo units with spare parts being supplied by L&J.

As you can see, the design features which have been engineered by L&J provide for application versatility and ease of service...both of which prove that the MCG 1500SFI is Engineered to Perform.