Delavan - Liquid Level Gauge Controllers - Liquid Level Control Switches and Process Instrumentation We supply ultrasonic, capacitance and microwave point level and continuous level messurement for liquids & solids. L&J Technologies


L&J Technologies
Delavan Home

Products:
Usage Reference Charts
Ultrasonic Probes
  110
  120
 1000
 1100
 220
Microwave
 320
R.F. Capacitance Probes
 410
 4100
 420
 421
 Versa-Cap
 500
 500-R
 510
 511
 514
 520
 800
Sensors & Probes
 110 Sensors
 1100 Sensors
 320 Sensors
 400 Series
 500 Series

PDF's
Site Map

Search: Delavan




Companies:
 Durlam
 GPE
 L&J Engineering
 Omnitrol
 Shand&Jurs
 Shand&Jurs BioGas

L&J Technologies is ISO 9001 Registered



Delavan
CAP ANALOG 4100

R.F. Capacitance Two-Wire Level Transmitter


Delavan CAP ANALOG 4100 - R.F. Capacitance Two-Wire Level Transmitter
See Optional Sensing Probes
  • True “two-wire” 24 Volts DC operation
  • Built-in immunity to process build-up/coatings
  • Switch selectable reversible output 4-20mA or 20-4mA
  • Completely adjustable
  • One time “zero-cal” function test
  • 1 mile twisted pair separation
  • Easy access NEMA 7, 9 enclosure
  • Economical and cost effective
  • Self-contained integral electronics
  • Sensing probe lengths to 250 Ft.


PURPOSE
Delavan’s Cap Analog 4100 is a cost effective “Two- Wire” R.F. Capacitance Transmitter used in powder bulk solids, liquids and slurry applications.

TRUE “TWO-WIRE” OPERATION
The Cap Analog 4100 is a superior two-wire transmitter. Maintenance and installation expense are eliminated due to not needing line power; the same two wires which power the 4100 also transmit its output signal.

PRINCIPLE OF OPERATION
The Cap Analog 4100 system consists of an electronic amplifier mounted in a cast aluminum explosion proof housing. This housing normally is integrally mounted on the top of the probe. The unit is powered by a remote 24 DC power supply, supplied by Delavan or the user.

The Cap Analog 4100, along with its probe sensor, operates as a capacitance system that converts changes in level to changes in output signal. After calibration, any change in level is recognized and converted to an analog output 4-20mA signal. The system will operate any loop powered 4-20mA DC indicator.

The Cap Analog 4100 is supplied with two 20 turn, ZERO and SPAN adjust potentiometers. A switch and memory calibration potentiometer is provided. DIP switches are provided to extend the range of zero reverse output so that output is 20-4 instead of 4-20mA DC



Delavan